  • Lot 5181

    2019 Cat XQ60 59.4 kVA Mobile Generador

    Tipton, CA

    Uso: 4989 hrs


    Cat 4 Cylinder 56 kW Diesel Engine • 59.4 kVA/47.5 kW Rated 3 Phase Output • 480 V / 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • S/A Trailer • Lunette Ring

    Subasta programada

    SOLD
  • 2011 Wacker Neuson G120 96 kW Mobile Generador
    Lot 5176A

    John Deere 4 Cylinder Diesel Engine • 120 kVA/96 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 70 kVA •/70 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 230 V & 400 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2020 Generac MDG25IF4 17.5 kW Mobile Generador
    Lot 5184

    Isuzu 5 Cylinder Diesel Engine • 25 kVA/ Rated 3 Phase Output • 240 V & 120 V Receptacles • S/A Trailer • Ball Hitch

    Subasta programada

    SOLD
  • 2011 Wacker Neuson G100 80 kW Mobile Generador
    Lot 5177A

    John Deere 4.5 L Diesel Engine • 100 kVA/80 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 61 kVA •/61 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2018 Multiquip DCA25SSIU4F 20 kW Mobile Generador
    Lot 5185

    Isuzu 4 Cylinder 2.1 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • / 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • S/A Trailer • Lunette Ring

    Subasta programada

    SOLD
  • 2005 Multiquip DCA70SSJU 70 kW Mobile Generador
    Lot 5179

    John Deere 4 Cylinder Diesel Engine • 70 kVA/40 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • /40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2010 Wacker Neuson G70 58 kW Mobile Generador
    Lot 5178

    2008 US EPA Label • John Deere 4 Cylinder 4.5 L Diesel Engine • 58 kVA/72 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 46 kVA •/46 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2010 Wacker Neuson G100 80 kW Mobile Generador
    Lot 5187

    2010 US EPA Label • John Deere 4045HF285H 4 Cylinder 4.5 L Diesel Engine • 100 kVA/80 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 60 kVA •/60 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2008 Wacker G-50 38 kW Mobile Generador
    Lot 5181A

    John Deere 4 Cylinder 2.4 L Diesel Engine • 48 kVA/38 kW Rated 3 Phase Output • 208 V / 480 V Rated Voltage • 32 kVA •/323 kW • Rated Single Phase Output • 120 V / 420 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2012 Magnum 35 26 kW Mobile Generador
    Lot 5182

    John Deere 4 Cylinder 37 kW 2.4 L Diesel Engine • 33 kVA/26 kW Rated 3 Phase Output • 208 V / 480 V Rated Voltage • 25 kVA •/25 kW • Rated Single Phase Output • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2011 Magnum MMG35FH 26 kW Mobile Generador
    Lot 5183

    2012 US EPA Label • John Deere 4024TF281B 4 Cylinder 2.4 L Diesel Engine • 26 kVA/33 kW Rated 3 Phase Output • 208 V / 480 V Rated Voltage • 25 kVA •/25 kW • Rated Single Phase Output • 240 V Rated Voltage • 120 V Receptacles • Bottom Mounted Fuel Tank • S/A Trailer • Ball Hitch • Surge Brakes

    Subasta programada

    SOLD
  • 2010 Wacker Neuson G100 80 kW Skid-Mounted Generador
    Lot 5186A

    2010 US EPA Label • John Deere 4 Cylinder Diesel Engine • 100 kVA/80 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 60 kVA •/60 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank

    Subasta programada

    SOLD
  • 2008 Wacker G160 128 kW Mobile Generador    (Inoperable)
    Lot 6401A

    John Deere 4 Cylinder Diesel Engine • 160 kVA/128 kW Rated 3 Phase Output • 208 V / 480 V Rated Voltage • 75 kVA •/75 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank • T/A Trailer • Lunette Ring • Surge Brakes

    Subasta programada

    SOLD
  • 2010 Wacker Neuson G240 191 kW Skid-Mounted Generador    (Inoperable)
    Lot 5186

    2010 US EPA Label • John Deere 6.8 L Diesel Engine • 270 kVA/ Rated 3 Phase Output • 133 V / 230 V / 265 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank